ZheJiang DaMing New Material Joint Stock Co,LTD.
ADD : No. 166, Golf Road, Yinhu Street, Fuyang District, Hangzhou City, Zhejiang Province.
Phone: +86 150 6812 9966 Miss Yuan
Tel: +86 571 2320 8118
E-MAIL : info@zjdmxc.com
Parallel constant wattage heating cable
Parallel constant wattage heating cable can be used for pipe and equipment freeze protection and process temperature maintenance requiring high power output or high temperature exposure.This type provide an economical alternative to self regulating heating cable but requires more skill for installation and more advanced control and monitor system.Constant wattage heating cables can provide process temperature maintenance up to 150℃ and can withstand exposure temperature up to205℃ with power on.
Product specification and model
Parallel constant wattage heating cable
Structure
HGW single phase constant wattage heating cable used to freeze protection,heat preservation for all kinds of pipelines and instruments.Application such as factory Zone 1,Zone 2 explosive gas atmosphere area.
1.Tinned copper stranded wire 2.FEP insulation layer 3.FEP insulation layer
4.Ni-Cr alloy wire 5.FEP insulation layer 6.Tinned copper metal braid
7.FEP outer sheath
Working principle
Two paralleled stranded copper wire as the bus wires with insulion layer FEP ,then wrap the nickel-chromium alloy as the heating wire connet with bus wires at regular intervals,from the parallel resistance,finally covered with insulion jacket FEP.When the bus wires power on,each parallel resistance begin to heat,thus form a continuous heating cable.
Product specification and technical features
Part Number |
Rated power(W/m) |
Max Usage length(m) |
Max maintenance temperature(℃) |
Sheath color |
|
Common model |
Strengthen model |
||||
HGWF-10/2P |
HGWF-10/2J |
10 |
210 |
150℃ |
red |
HGWF-20/2P |
HGWF-20/2J |
20 |
180 |
120℃ |
red |
HGWF-30/2P |
HGWF-30/2J |
30 |
150 |
90℃ |
red |
HGWF-40/2P |
HGWF-40/2J |
40 |
140 |
65℃ |
red |
Rated voltage: 220V/380V/660V
Max exposure temperature:205℃
Normality insulation resistance:≥20M ohm
Protection level:IP54
Dielectric strength:2000V 50Hz/1min
Size:6.3x9.5mm
Insulation material:FEP
Approvals:CE EX
Three phase constant wattage heating cable
Three phase constant wattage heating cable can adopt three phase triangle power supply,has the characteristics of single phase constant power heating cable.Special used for long distance and large diameter pipelines heat traceing and preservation.Application such as factory Zone 1,Zone 2 explosive gas mixture T3 area.
Parallel constant wattage heating cable
1.Tinned copper stranded wire 2.FEP insulation layer 3.FEP insulation layer
4.Ni-Cr alloy wire 5.FEP insulation layer 6.Tinned copper metal braid
7.FEP outer sheath
Working principle
Three paralleled stranded copper wire as the bus wires with insulion layer FEP ,then wrap the nickel-chromium alloy as the heating wire connet with bus wires at regular intervals,repeated cycle connection (like:AB-BC-CA-AB) from the parallel resistance between two phase,finally covered with insulion jacket FEP.When the bus wires power on three phase,each parallel resistance begin to heat,thus form a continuous heating cable.
Product specification and technical features
Part Number |
Rated power(W/m) |
Max Usage length(m) |
Max maintenance temperature(℃) |
Sheath color |
|
Common model |
Strengthen model |
||||
HGWF-30/3P |
HGWF-30/3J |
30 |
330 |
120℃ |
red |
HGWF-40/3P |
HGWF-40/3J |
40 |
280 |
110℃ |
red |
HGWF-50/3P |
HGWF-50/3J |
50 |
275 |
80℃ |
red |
HGWF-60/3P |
HGWF-60/3J |
60 |
250 |
60℃ |
red |
Rated voltage: 380V/660V/1100V
Max exposure temperature:205℃
Normality insulation resistance:≥20M ohm
Protection level:IP54
Dielectric strength:2500V 50Hz/1min
Size:6.3x12mm
Insulation material:FEP
Approvals:CE EX